Home > Equipment, IT > NexGen and Sage Endec Control

NexGen and Sage Endec Control

December 5, 2012

We installed the RCS NexGen a year ago.  As of today we still have issues with the NexGen – Sage Endec communications.

Our NexGen system is installed with no GPIO, or opto-relay, equipment.  We are 100% IP control with the system at this time.  We run EAS Required Weekly Tests, generated from the NexGen, without any issues.  It is pretty simple once set up.  NexGen is configured to look at the IP address and Port  of the Sage Endec, monitoring for any Sage originated activity.  If an alert or Required Monthly Test (RMT) comes in, NexGen is supposed to “see” it and act accordingly.  It works sporadically at best.  Today we had 2 of 3 stations run properly.

What could be the problem?  No one seems to know or ask the proper questions.  We have tested time and again the Sage Endec for the information it sends out.  It exists.  It’s there.  It just needs to be acted upon.  The NexGen will not “see” the information.  It does not acknowledge that an alert or test has come in.  If  it does, it works just fine.  If it doesn’t, then manual intervention is required or the Sage takes over and runs the alert or test on the air, interrupting programming.

I ask the question: Why does the NexGen machines not see the information consistently?  It is there to be acted upon, so why does it not see it?  NexGen is installed on Windows 7 server class computers.  NexGen runs on layers of older code.  I conclude one of two things:  1) the older IP stack on which NexGen is build stops responding, or 2) the Windows 7 computer “shuts down” something such that the information is ignored.  Anyone have experience with Windows 7 boxes acting odd like this?  Could there be a miscue between the application and the physical NIC?

We continue to send logs to RCS for evaluation.  No one seems to have answer.  One year later.  Any Windows 7 insight is greatly appreciated, and if you have an RCS NexGen running IP control, let me know what experiences you have.

 

Cheers!

 

Categories: Equipment, IT Tags: , ,
  1. Stephen
    March 10, 2013 at 13:56

    Can you tell me how in the world you got the Endec to take an RWT from NexGen over IP??! I have events forwarding and the box and NexGen cooperate on a RMT or any other even I have set to forward, but for the life of me I cannot figure out how to generate a RWT that NexGen sends to the Sage over IP. The folks at RCS Support were not helpful, as they tried to convince me that RWTs are events that are forwarded from the Sage box, not generated in or triggered by NexGen. Not wanting to go in to an EAS 101 class with the tech I gave up with them… Any hints would be greatly appreciated.

  2. March 10, 2013 at 14:55

    Stephen,
    This is a very good question and deserves time to respond. To do that I need to sit in front of NexGen and maybe even grab screen shots.
    Rest assured, I will respond within the week and maybe it will make sense.

    Interesting that you cannot find a tech at RCS that can help. I know the one that helped us is no longer there.

    Stay tuned!

    Bill

  3. May 21, 2013 at 12:37

    I visit day-to-day some web pages and websites to read articles,
    except this web site offers quality based
    content.